What is the difference between UL1007 wire and UL1015 wire
2021-11-28
What is the difference between UL1007 wire and UL1015 wire?
There are 2 difference between them.
1. Different withstand voltage: the voltage of UL 1007 wire is 300V for 1007 and it is 600V for UL1015 wire; Therefore, the insulation thickness is different, 1015 wire is much thicker.
2. Different temperature resistance: Ul1007 wire is 8 but Ul1015 is 10.
The wire is composed of one or several soft wires, which are covered with a light and soft protective layer; The cable is composed of one or several insulated conductors, which are covered with a tough outer layer made of metal or rubber. Cables and wires are generally composed of three parts: core wire, insulating sheath and protective sheath.
Wire structure:
Ul1007 electronic wire structure consists of insulating layer and conductor, covered with PVC insulating layer, and the full Chinese name is PVC; Internal conductors shall be divided into bare copper and tinned copper according to normal standards. Product requirements: rated temperature: 80 ° C, rated voltage: 300V, must pass UL VW-1 and CSA FT1 vertical flame resistance test, and the insulation thickness is uniform.
Ul1007 electronic wire:
Specification of regular wire conductor:
UL 1007 electronic wire is the internal wiring of electrical equipment. In the field of producing ul1007 electronic wire, the general nominal unit is AWG (American wire gauge). The wire diameter specifications of common regular wires are shown in the table below:
Model wire gauge wire number / wire diameter outer diameter insulation thickness outer diameter of conductor
1007 30 7/0.1 0.3 0.41 1.12
1007 28 7/0.127 0.38 0.41 1.20
1007 26 7/0.16 0.48 0.41 1.30
1007 24 11/0.16 0.61 0.41 1.43
1007 22 17/0.16 0.76 0.41 1.58
1007 20 26/0.16 0.94 0.41 1.76
1007 18 41/0.16 1.18 0.41 2.00
1007 16 26/0.254 1.49 0.41 2.32
UL 1007 electronic wire composition:
It includes two parts: insulating layer and conductor. The outer cover is PVC insulating layer. The full Chinese name of PVC is PVC; Internal conductors shall be divided into bare copper and tinned copper according to normal standards.
Product requirements:
Rated temperature: 80 ° C, rated voltage: 300V, must pass UL VW-1 and CSA FT1 vertical flame resistance test, and the insulation thickness is uniform.
Product basis: the product is produced and tested according to UL758 standard (including temperature resistance, pressure resistance, aging and other tests).
Ul1015 electronic wire:
Specification of regular wire conductor:
The general nominal is in AWG (American wire gauge), and the wire diameter specifications of common normal wires are shown in the table below:
There are 2 difference between them.
1. Different withstand voltage: the voltage of UL 1007 wire is 300V for 1007 and it is 600V for UL1015 wire; Therefore, the insulation thickness is different, 1015 wire is much thicker.
2. Different temperature resistance: Ul1007 wire is 8 but Ul1015 is 10.
The wire is composed of one or several soft wires, which are covered with a light and soft protective layer; The cable is composed of one or several insulated conductors, which are covered with a tough outer layer made of metal or rubber. Cables and wires are generally composed of three parts: core wire, insulating sheath and protective sheath.
Wire structure:
Ul1007 electronic wire structure consists of insulating layer and conductor, covered with PVC insulating layer, and the full Chinese name is PVC; Internal conductors shall be divided into bare copper and tinned copper according to normal standards. Product requirements: rated temperature: 80 ° C, rated voltage: 300V, must pass UL VW-1 and CSA FT1 vertical flame resistance test, and the insulation thickness is uniform.
Ul1007 electronic wire:
Specification of regular wire conductor:
UL 1007 electronic wire is the internal wiring of electrical equipment. In the field of producing ul1007 electronic wire, the general nominal unit is AWG (American wire gauge). The wire diameter specifications of common regular wires are shown in the table below:
Model wire gauge wire number / wire diameter outer diameter insulation thickness outer diameter of conductor
1007 30 7/0.1 0.3 0.41 1.12
1007 28 7/0.127 0.38 0.41 1.20
1007 26 7/0.16 0.48 0.41 1.30
1007 24 11/0.16 0.61 0.41 1.43
1007 22 17/0.16 0.76 0.41 1.58
1007 20 26/0.16 0.94 0.41 1.76
1007 18 41/0.16 1.18 0.41 2.00
1007 16 26/0.254 1.49 0.41 2.32
UL 1007 electronic wire composition:
It includes two parts: insulating layer and conductor. The outer cover is PVC insulating layer. The full Chinese name of PVC is PVC; Internal conductors shall be divided into bare copper and tinned copper according to normal standards.
Product requirements:
Rated temperature: 80 ° C, rated voltage: 300V, must pass UL VW-1 and CSA FT1 vertical flame resistance test, and the insulation thickness is uniform.
Product basis: the product is produced and tested according to UL758 standard (including temperature resistance, pressure resistance, aging and other tests).
Ul1015 electronic wire:
Specification of regular wire conductor:
The general nominal is in AWG (American wire gauge), and the wire diameter specifications of common normal wires are shown in the table below:
UL Style
|
|
|
|
|
|
&
|
Conductor
|
Insulation
|
Overall
|
Stand Put-up
|
Conductor
|
CSA Type
|
Thickness
|
Diameter
|
Resistance at 20℃
|
||
AWG
|
NO/mm
|
mm
|
mm
|
M/coil
|
Ω/km
|
28
|
7/0.127
|
0.79
|
2.0±0.10
|
610
|
223
|
26
|
7/0.160
|
0.79
|
2.10±0.10
|
610
|
139
|
24
|
11/0.160
|
0.79
|
2.20±0.10
|
610
|
88.7
|
22
|
17/0.160
|
0.79
|
2.40±0.10
|
610
|
57.4
|
20
|
21/0.178
|
0.79
|
2.50±0.10
|
610
|
37.1
|
18
|
34/0.178
|
0.79
|
2.80±0.10
|
610
|
23.7
|
16
|
26/0.254
|
0.79
|
3.10±0.10
|
610
|
14.2
|
14
|
41/0.254
|
0.79
|
3.50±0.10
|
610
|
9.63
|
12
|
65/0.254
|
0.79
|
4.0±0.10
|
610
|
6.06
|
10
|
105/0.254
|
0.79
|
4.60±0.10
|
610
|
3.8
|

Related News
The cause analysis and solution of oxidation of harness wire
2022-03-30 1002the advantage of medical connectors
2022-03-28 854what is the function of auto wiring harness?
2022-03-25 868Precautions for wire and cable installation
2022-03-21 854How to solve these five problems in PVC cable material?
2022-03-13 834what is the advantage of the waterproof connectors?
2022-03-10 719How to install home improvement wires?
2022-03-08 797Common power cables and communication cables
2022-03-06 681